Product Applications

Discover our range of remedial and retrofit solutions for brick, soft-stone and concrete masonry buildings with our interactive headquarters. Click on each letter (A-R) for an example application schematic that provides simple, best-practice details that can be adopted for your project.

Please note this does not show an exhaustive list of applications, if you're unsure about an application, please contact us at info@pythonfixings.com.au or 1800-PYTHON.

For more information, request a comprehensive set of example construction details and engineering design data/capacity tables here.

 
PYTHON Product Applications for strengthening and retrofitting brick and concrete masonry structures Steel angle parapet fixing detail (PS606) Securing capping stone and ornamental features (PS405) Securing canopy with PYTHON Plates (PS802) Floor diaphragm connection with PYTHON Plates (PS801) Window infill connection with PYTHON C (PS406) Steel beam fixing onto masonry (PS605) PYTHON C Fixing tying 2+1 Cavity from outside (PS102) and PYTHON MT Fixing 340mm tying 2+1 Cavity from inside (PS103) PYTHON C Fixing tying 1+1 Cavity (PS102) Timber strong back fixing to cavity wall with PYTHON MT Fixing 340mm (PS304) Steel strong back fixing onto masonry (PS607) Timber strong back fixing onto concrete masonry (PS501) Securing veneer onto concrete wall (PS403) Foundation starter studs (PS702) Timber strong back on solid masonry (PS301) Timber diaphragm on masonry (PS201) Roof connection to masonry (PS202) Starter studs for concrete or shotcrete overlay (PS701) CLT connection to masonry (PS305)

PYTHON Product Applications

Backed by cutting-edge testing and research on earthquake retrofits, PYTHON products facilitate an extensive range of strengthening methods for existing brick and concrete masonry structures, from the front facade all the way to the rear.

Part 1.0: Building Front

Steel angle parapet fixing detail (PS606)

PYTHON MT Fixings 340mm are installed vertically to connect a steel member. PYTHON MT Fixings are used with PYTHON washers.

Securing capping stone and ornamental features (PS405)

PYTHON MT Fixings 340mm are vertically installed to connect capping stone. PYTHON C Fixings are used to restrain the ornamental feature.

Securing canopy with PYTHON Plates (PS802)

PYTHON Masonry Retrofit Plates are used to secure a canopy. The application includes an eye nut connection and canopy brace.

Floor diaphragm connection with PYTHON Plates (PS801)

PYTHON Masonry Retrofit Plates are used for a wall-to-floor or roof connection with through plates. The application includes a timber joist, joist plate and anchor rod.

Window infill connection with PYTHON C (PS406)

PYTHON C Fixings are installed into mortar joints to connect new brick infill within an existing window opening.

Part 2.1: Building Middle

Steel beam fixing onto masonry (PS605)

PYTHON MT Fixings connect a horizontal steel section or member to masonry. PYTHON MT Fixings can be used with or without PYTHON washers, as determined by the designer.

PYTHON C Fixing tying 2+1 Cavity from outside (PS102)

PYTHON C Fixings are recessed in brick from outside the building. The application consists of an external single brick layer, a 50mm air cavity and a double brick layer.

PYTHON MT Fixing 340mm tying 2+1 Cavity from inside (PS103)

PYTHON MT Fixings 340mm are recessed in brick from inside the building. The application consists of a double brick layer, a 50mm air cavity and an external single brick layer.

PYTHON C Fixing tying 1+1 Cavity (PS102)

PYTHON C Fixings are recessed in brick to tie a 1+1 cavity. The application consists of a single brick layer, a 50mm air cavity and an external single brick layer.

Timber strong back fixing to cavity wall with PYTHON MT Fixing 340mm (PS304)

PYTHON MT Fixings 340mm are countersunk in timber to connect a timber strong back to cavity clay brick masonry.

Part 2.2: Building Middle

Steel strong back fixing onto masonry (PS607)

PYTHON MT Fixings connect a steel frame to a masonry wall. The connection can be directly fixed through a flange or through a welded cleat.

Timber strong back fixing onto concrete masonry (PS501)

PYTHON MT Fixings are countersunk in timber to connect a timber strong back to concrete masonry.

Securing veneer onto concrete wall (PS403)

PYTHON C Fixings are recessed in brick to secure veneer onto a concrete wall. The fixing heads are recessed within the brick, with a minimum 30mm edge distance and avoiding the mortar joint.

Foundation starter studs (PS702)

PYTHON MT Fixings 340mm are used as starter studs into a masonry wall. The application includes a new reinforced concrete foundation.

Part 3.0: Building Rear

Timber strong back on solid masonry (PS301)

PYTHON MT Fixings are countersunk in timber to connect a timber strong back to solid clay brick masonry.

Timber diaphragm on masonry (PS201)

PYTHON MT Fixings with PYTHON washers are used for a timber diaphragm connection to masonry. Timber blocking is sized to suit the existing joist depth.

Roof connection to masonry (PS202)

PYTHON MT Fixings with PYTHON washers are used for a roof connection to masonry. Timber blocking is sized to suit the existing purlin depth.

Starter studs for concrete/shotcrete overlay (PS701)

PYTHON MT Fixings are used as starter studs for a shotcrete or in-situ concrete pour. The application includes reinforcing bars, a clay brick wall and a shotcrete or concrete overlay.

CLT connection to masonry (PS305)

PYTHON MT Fixings connect plywood or CLT panels directly over masonry and DPC.

The applications shown herein are for illustration purposes and do not replace engineering calculations. For more details on these applications refer to the PYTHON Example Application Details Library.

 

SPECIALIST TECHNICAL SUPPORT

OUR EXPERT ENGINEERING TEAM CAN PROVIDE ADVICE ON STRUCTURAL DETAILS AND DESIGN

ON-SITE PRE- AND POST-INSTALLATION QUALITY ASSURANCE TESTING